Specifications
Fire Brick Lined Front Loading Natural Draft Kilns
|
|
Model
Number |
DLB-40 |
|
Inside
Volume -Cu.Ft. |
60 |
|
Setting
Space-Cu.Ft. |
40 |
|
Setting Area-Inches
|
W
D H
37x37x52 |
|
Inside
Dimension-Inches |
48x45x52 |
|
Outside
Dimension-Inches |
65x78x83 |
|
Instrumentation
(Microprocessor Controller Optional
Equipment) |
DD1
Controller |
|
Stacking
Height-Inches |
52 |
|
Temperature
Range |
0-2500�
F. |
|
Shelf
Size-Inches Per Level |
4-18x18
or
2-12x18 & 3-12x24 |
|
Maximum
BTU/HR. Input |
499,000 |
|
Maximum
Gas Consumption CFH |
600 |
|
Minimum
Gas Pressure |
6
Inches Water Column Pressure |
|
Gas
Line Inlet Inches |
1 |
|
Number
of Burners |
8 |
|
Average
Firing Time-Cone 06 |
6
Hours |
|
Average
Firing Time-Cone 10 |
8-10
Hours |
|
Approximate
Shipping Weight |
4,600
lbs. |
Electrical
hook-up required on all kilns. No extra charge for
kilns firing with propane gas. Please specify.
Specifications subject to change without notice.
Patent 4,531,910 ETL